MIF (General)takaaki.yokozawa - 8:43 Saturday 07 December 2024 (31940)
Print this reportIFO status 241207This morning, I noticed the LSC_LOCK guardian stopped LOCK_PREP state (requested PRFPMI_RF_LOCKED) due to the IMC cannot be locked. From the image of the IMT TRANS, the alignment of the pitch was quite bad, but the oplev values didn't jump. I checked the PZT feed back signal one by one and finally K1:IMC-PZT2_PIT_OUTPUT jumped a lot. After recovered this value, IMC can be locked. Also, PRFPMI_RF_LOCKED state recovered.
I tried to find the reason of this jump, but I cannot find the reason from the Seismometer as shown in Fig.1. Some investigation would be necessary.