kenta.tanaka - 21:30 Wednesday 27 November 2024 (31819) Print this report
Health check: BS

BS health check was done.

Unfortunately, BF GAS was not performed.

The gain of IM V1 response seems to be several dB lower. Many peaks appears from 2 Hz to 7Hz when TM coils excited.

The others seem to be healthy.

Images attached to this report
Comments to this report:
ryutaro.takahashi - 13:56 Thursday 28 November 2024 (31844) Print this report

Though the gain of IM V1 response is lower than the reference by 2~3dB, this situation is the same as the last health check.

ryutaro.takahashi - 22:24 Thursday 05 December 2024 (31919) Print this report

After replacing the function generator for the LVDT driver, the health check was performed. The BF GAS was not performed. Q of F0 and F1 GAS were increased. The coupling from Y to V at 0.2Hz was decreased in IM. The others look healthy.

Images attached to this comment
ryutaro.takahashi - 12:57 Friday 06 December 2024 (31925) Print this report

 The coupling from P to V was larger than the reference in IM. This situation is the same as the last measurement. Compared with other coupling passes, the reference level is too small.