Reports 1-1 of 1 Clear search Modify search
DetChar (General)
hirotaka.yuzurihara - 13:44 Thursday 05 September 2024 (30987) Print this report
Segment for lockloss of LSC_LOCK guardian

I prepared the segment file for lockloss of LSC_LOCK guardian. The script generates the segment every 15 minutes.

The segment generated before 9:00 JST is stored in /users/DET/Segments/K1-GRD_LSC_LOCK_LOSS/2024 . The today's segment file (under the update) is stored in /users/DET/tools/Segments/Script/Partial .
This is a list of the times when the LSC_LOCK guardian was in the LOCK_LOSS state (-10).
Also, the summary page is convenient to check when the lock loss happened: (1) visit the sumary page (2) open the LOCK_LOSS table in 'state details' loated below. (Fig)