Simulation of OMC stack with fixing

As requested in the lase ISC meeting, I simulated the resonant mode of one of OMC stack leg with fixing some of them. I simulated three cases:

  1. All of thee stages are fixed
  2. The bottom and the middle stages are fixed, the top stage is free
  3. The middle and the top stages are fixed, the bottom stage is free

In the following posts I will show the results of each case.

Please note that with the software I used for these simulations (Autodesk Fusion) it is impossible to simulate the frequency response of the displacement. To do so we need different software, such as COMSOL, ANSYS, etc. I already prepared one of them (Autodesk Inventor Nastran), but it will take long time because I have to learn how to use them and I'm just busy.

Comments to this report:
satoru.takano - 1:23 Wednesday 07 August 2024 (30741) Print this report

Case1: all of the stages are fixed

No. Frequency [Hz] Shape
1 3.50 Common X
2 3.51 Common Y
3 4.381 Common RZ
4 13.428 Common RY
5 13.502 Common RX
6 38.382 Common Z

 

Images attached to this comment
satoru.takano - 1:29 Wednesday 07 August 2024 (30742) Print this report

Case2: the bottom and the middle stages are fixed

No. Frequency [Hz] Shape
1 2.971 Common X
2 2.978 Common Y
3 3.803 Common RZ
4 9.72 Differential X?
5 9.735 Differential Y?
6 11.418 Differential RZ
7 18.29 Common RY?
8 18.344 Common RX?
9 31.531 Common Z
10 63.557 Differential RY?
11 63.971 Differential RX?
12 98.154 Differential Z

 

Images attached to this comment
satoru.takano - 1:36 Wednesday 07 August 2024 (30743) Print this report

Case3: the middle and the top stages are fixed

No. Frequency [Hz] Shape
1 2.708 Common X
2 2.714 Common Y
3 3.444 Common RZ
4 10.472 Common RY?
5 10.498 Common RX?
6 14.58 Differential RZ
7 17.208 Differential X?
8 17.217 Differential Y?
9 29.12 Common Z
10 110.618 Differential RY
11 111.256 Differential RX
12 131.803 Differential Z

 