Reports 1-1 of 1 Clear search Modify search
PEM (Center)
tatsuki.washimi - 15:05 Friday 19 July 2024 (30473) Print this report
Comment to Preparation of the small shaker near the OMC area (30383)

[Takano, Washimi]

We performed shaker injection tests for the OMMT-OMC duct, remotely from the control room.

Fig.1 is the spectrograms of 70-200Hz and 70-100Hz swept sine injection test. DAC amplitude was 40 counts.
At 82Hz and 92Hz, broadband excess were found in the OMC TRANS.

Fig.2 and Fig.3 are the results of the single line injection for these frequencies.

Images attached to this comment
Search Help
×