Reports 1-1 of 1 Clear search Modify search
VIS (PR2)
ryutaro.takahashi - 19:16 Friday 14 June 2024 (29918) Print this report
Comment to PR2 vertical OSEM is almost out of range. (29881)

I adjusted the height of the SF and BF keystone so that the IM V1 OSEM could be in the linear range. Though the BF setpoint was changed by -1500, the IM V OSEMs were changed by only 176~275. The deviation of the BFD V (+910) was also inconsistent with the SF setpoint change (+1500).

  Before [um] After [um]
IM V1 -461 -186
IM V2 -271 -95
IM V3 -254 -24
SF setpoint -3000 -1500
BF setpoint 862.8 -637.2
BFD V 154 1064

 

Search Help
×