After ETMY finalization work (klog29604), I noticed ETMY F2 GAS filter is very glitchy (fig1).
I checked F2 GAS LVDT spectra at several timing and confirmed the time when the problem happened.
Figure 2 shows the spectra of F2 GAS LVDT at 10:44 (blue) and 10:45, so LVDT signals got strange around 10:45.
Figure 3 shows the time series data of GAS signals around 10:45 JST.
Left and right cursors show 10:44 and 10:45 today, respectively.
Since the gurdian state is ISOLATED state, this time seems before our work (we requested SAFE state later, maybe around 10:50).
Also, RMS of GAS signals was reduced from 10:45, which is probably corresponding to the timing when I stopped the dry air injected to EYC.
I'm not so sure why stopping dry air caused glitcies on F2 GAS signals but anyway I have already asked Takahashi-san to check the situation.