Reports 1-1 of 1 Clear search Modify search
VIS (EY)
ryutaro.takahashi - 19:24 Thursday 09 May 2024 (29451) Print this report
Investigation of BF horizontal actuator

[Takahashi, Ikeda, Hirata]

We investigated the small horizontal actuation problem in the BF damper. Particularly, the efficiency of the H1 actuator was too small (2um/1000count). We checked the following points.

  1. Resistance and inductance of the primary and secondary coils: They were normal.
  2. Cabling around the H1 coils: There was a small change in the LVDT signal by touching the connection points.
  3. Coil driver and LVDT combiner: The efficiency of the H1 coil was still small by swapping the channels of H1 and H2.

Finally, we found that a cable at the Dsub connector on the BF side plate was touching the bracket for the secondary coils of the H1 LVDT. The cable was treated to keep a gap from the bracket. When the cable was released from touching, the BF rotated much in yaw. We offloaded the BF with the F0 yaw FR.

Images attached to this report
Search Help
×

Warning

×