Reports 1-1 of 1 Clear search Modify search
CRY (Cryo-payload IX)
takafumi.ushiba - 21:43 Monday 01 April 2024 (29040) Print this report
Finalization of ITMX payload Day1: Recovery of ALIGNED state and check of EQ stops

[Yokozawa, Ushiba]

We checked IX payload and found that one of EQ stops from MNR was touched to MN (fig1).
So, we moved EQ stop not to hit MN and then suspension can be aligned state.

Then, we adjusted all EQ stops and take photos for the record.
Photos can be seen from the following link:
https://www.dropbox.com/scl/fo/o4pp1ednlbpmlt8ldzcei/h?rlkey=xwwrpcc8takxpj1ca63jsjor1&dl=0

We haven't finished OpLev path check yet, so we need to do it at some point.

Images attached to this report
Comments to this report:
takaaki.yokozawa - 7:22 Tuesday 02 April 2024 (29041) Print this report
I added the more 25 pictures for the EQ stopper at ITMX -Y side.
https://www.dropbox.com/scl/fo/i61a48x9lcxpx1u6xv9qc/h?rlkey=a150lmvbtzn19x30fthfqxkv9&dl=0
Search Help
×

Warning

×