I confirmed GRX can reach at EX.
Setpoint difference between current good and past good (before the earthquake) is as follows:
pitch: -9.5 (before) -> 22.3 (after)
yaw: -61.6 (before) -> -64.2 (after)
Figure 1 shows the time series data of TRX GR PD after PR3 alignment,
Top shows GRX PD signals and bottom shows GRX shutter status, which was closed around t = -18m45s.
Note:
Currently GV between Xarm and IXA, and BS and IXC, so the godd value changes might be due to not only the earthquakes but also GV closure.
Anyway, several tens of urad change is not so large (can be explained by GV closure), so POP tabe, PR2 suspended table, and PR3 OpLevs don't seem moved so much.