Reports 1-1 of 1 Clear search Modify search
DetChar (General)
Shunsei Yamamura - 20:11 Friday 09 February 2024 (28568) Print this report
Investigation of scattered light noise in O4a
I investigated the scattered light noise in O4a again, using data during 2023/6/18 23:00 ~ 6/19 1:00 (UTC), where I hadn't checked yet. 
As a result, some scattered light noise was found as the PRM motion increased.
Details were summarized in a slide. Please see JGWdoc.
Comments to this report:
Shunsei Yamamura - 19:20 Wednesday 14 February 2024 (28584) Print this report
I plotted sensitivitity curves and computed the inspiral range comparing the data with and without scattered light noise.
I used data during 6/18 3:25-3:40 UTC as "without scattered light noise" and 6/18 23:00-6/19 4:45 (every 15 min) as "with scattered light noise."
Please see DACwiki for plots.
Search Help
×