Reports 1-1 of 1 Clear search Modify search
VIS (MCF)
ryutaro.takahashi - 17:44 Thursday 18 January 2024 (28320) Print this report
Recovery of MCi suspension

[Takahashi, Dan, Washimi, Akutsu]

We investigated the condition of the MCi suspension.

  • TM: All magnets were safe. One EQ stopper at X-Y+bottom was touching the TM.
  • IM: Any damping magnets were not touching the IM body.
  • Top stage: Both pitch and yaw stages with pico-motors didn't reach the actuation limit.

We need to remove the baffle at Y+ to adjust the EQ stopper. 

Images attached to this report
Comments to this report:
ryutaro.takahashi - 17:43 Friday 19 January 2024 (28335) Print this report

[Takahashi, Dan, Washimi, Akutsu]

We released the touching EQ stopper from the TM. The TM was aligned to the center of QPD for the Oplev with the pico-motors.

ryutaro.takahashi - 18:39 Tuesday 23 January 2024 (28379) Print this report

[Takahashi, Ikeda, Washimi]

One stopper at X-Y-bottom might be touching the TM during the health check.

We checked the side of the IM body by lifting the magnet box (IRM). The wire ends were not projecting out of the IM body.

Images attached to this comment