DetChar (General)nami.uchikata - 11:37 Tuesday 19 December 2023 (28010)
Print this reportOmicron triggers at System BI have produced Omicron triggers for the strain channel for the O4a period at System B. They are available at /home/detchar/triggers/K1/CAL_CS_PROC_DARM_STRAIN_DBL_DQ_OMICRON
There some failed segments that exceed the trigger rate 10000 Hz. Even if I raise the threshold value, Omicron still fails for those segments. The figures are examples of such segments, we see strange behaviors in Spectrogram and Q-transform (Pastavi).
Images attached to this report
Comments to this report:
nami.uchikata - 14:50 Thursday 25 April 2024 (29328)
Print this reportIt seems the failure is caused by glitches from the IPC error. I have already made segments that excludes the IPC error segments from the science mode. /home/detchar/Segments/K1-GRD_SCIENCE_MODE_NO_IPC_ERROR