Reports 1-1 of 1 Clear search Modify search
VAC (EY)
nobuhiro.kimura - 20:19 Monday 20 November 2023 (27679) Print this report
Y-end #35 Vacuum pump air-cooling modification

[KImura and M. Takahashi]
We changed the cooling method of #35 TMP from water-cooled to air-cooled.
The modified TMP is cooled by the newly installed air-cooled fan.
The water-cooled cooling unit removed from the #35 TMP will be used to cool the #34 TMP, whose cooling unit failed.

Images attached to this report
Comments to this report:
shinji.miyoki - 8:58 Tuesday 21 November 2023 (27687) Print this report

I added heater power by 600W with a Delonghi heater.

Search Help
×