masayuki.nakano - 18:22 Monday 25 September 2023 (26890) Print this report
ETMY Q measurement

[YamamotoM, NakanoM]

After locking the FPMI only with ETMX without ETMY, the ETMY Q value of 24kHz dramhead mode was measured as 1.70(4)e5.
The attached plots show the ringdown curve. Also, the detail of each measurement is shown in the attached txt file.

The measurement was done for 10 times with the script /users/Commissioning/Q_meas/Qmeas.py. This script switchs the excitation of the TM test, and record the gps time of each switching. Then, make the ringdown curve by processing the AS RF signal.

Images attached to this report
Non-image files attached to this report
Comments to this report:
Masayuki Yamamoto - 12:35 Tuesday 26 September 2023 (26906) Print this report

The resonant frequency was confirmed at 23.7419kHz.