I implemented the script to take TCam image (ITMX/ITMY/ETMX/ETMY) during mirror cooling.
- When launching the script, the state of LSC_LOCK guardian and pcal-x/y guadian will be stored. After finishing the script, the script will restore these states.
- Only when the pcal state number > 20, we request OFS_CLOSED_LOW_P state.
- It takes ~12 minutes (in total) to take 4 images for each mirror.
- At that time of waiting too long time for locking GreenX, the script will launch the ushiba-san's script (klog#25049) to find the good position of PR3/ITMX/ETMX for GreenX.
- During the operation tests, I didn' find any troubles.
usage
on workstation at control room,
- open terminal
- launch the following script ( /users/Commissioning/scripts/TCam/TCam_weekly_photo.py )
- wait until the message 'Done : requested PSL_LOCKED state to GRD-IO_REQUEST' appeared (it will take ~12 minutes.)