Reports 1-1 of 1 Clear search Modify search
DetChar (General)
Shunsei Yamamura - 17:22 Thursday 18 May 2023 (25289) Print this report
An investigation of Non-Gaussiannity on 5/16

!'m investigating of Non-Gaussianity of recent locked data and uploaded the result to JGWdoc.
I checked three features.

  • Feature 1 ; 14:21:00 UTC (1368282078) ; > ~ 200 Hz
    • I found that a glitch coincidence with this non-Gaussianity.
    • I will compare the glitch with the Omicron results.
  • Feature 2 ; 14:24:40 UTC (1368282298) ; 40 ~ 60 Hz
  • Feature 3 ; 14:45:40 UTC (1368283558) ; 40 ~ 60 Hz
    • Feature 2 & 3 behave similarly.
    • same frequency band (40~60 Hz)
    • no peak in whitened time series
    • ASDs get high values at the time.
Images attached to this report
Comments to this report:
hirotaka.yuzurihara - 22:21 Thursday 18 May 2023 (25296) Print this report

Just a comment. On the attached plot, we can see the non-Gaussianity with time dependency. This looks interesting! But, the cause might be a line noise with changing the central frequency, which is related to (klog# 2527)

Images attached to this comment
Search Help
×