DetChar (General)shoichi.oshino - 16:44 Thursday 18 May 2023 (25280)
Print this reportSummaryPage finalization for O4a[Yuzurihara, Yokozawa, Oshino]
We start to finalize the configuration of SummaryPage for O4a.
* GIF Remove plots of strainmeter and guardian because strainmeter channels are not maintained now.
* LSC_LOCK Add "RESET_ASC_FEEDBACK" and "LOCK_LOSS" state. https://gwdet.icrr.u-tokyo.ac.jp/~controls/summary/day/20230518/lock/lsc_lock/
* state order Set the state order to LSC Lock,Observing.
* DET Remove glitchgram.
* QPD Move to IMC and ISC tabs.
* Range Yamamoto-san started to DAQ of inspiral range, so the maximum plotting range is set to 3 Mpc. https://gwdet.icrr.u-tokyo.ac.jp/~controls/summary/day/20230518/lock/range/
Comments to this report:
shoichi.oshino - 16:43 Thursday 18 May 2023 (25286)
Print this report* PSL Reset plotting range of PSL QPD PIT to 0.05-0.15 and PSL QPD YAW to 0.2-0.3. Remove the unused "PSL table 06" channel. The reason why PSL plots had not been created recently was due to an error in the FIB plots. The nominal value of the FIB guardian had been changed, so that a different time was being analyzed than it should have been. This problem has been corrected. https://gwdet.icrr.u-tokyo.ac.jp/~controls/summary/day/20230518/psl/
shoichi.oshino - 15:07 Friday 19 May 2023 (25309)
Print this report* Home Remove the link to the Nightly page. Add a 3-hour guardian plot. https://gwdet.icrr.u-tokyo.ac.jp/~controls/summary/
* All guardian Add ALIGNMENT_RECORDER guardian. https://gwdet.icrr.u-tokyo.ac.jp/~controls/summary/day/20230519/lock/all_guardian_nodes/
* CRY Remove TM and BF temperature plots. https://gwdet.icrr.u-tokyo.ac.jp/~controls/summary/day/20230519/cry/location_order/
shoichi.oshino - 16:25 Monday 22 May 2023 (25326)
Print this report* Guardian Remove ALS_FIBX, ALS_FIBY, ALS_PLLX, and ALS_PLLY guardian plots.
* Pcal Add LSC Lock and Observing guardian.
* ASC modify plots of time series to auto-scale.
shoichi.oshino - 14:32 Tuesday 23 May 2023 (25337)
Print this report* IMC Modified guardian state Add trigger plot Add IMMT1 RTANS and MCE TRANS QPD time series
* LSC Move PD power plots to Arm cavity tab and change to normalized channels
* VIS Remove "aligned" state from all suspensions
* OMC Add OMC_LSC and OMC_ASC guardian state plots Expand the range of OMC trans power plot
shoichi.oshino - 16:48 Tuesday 23 May 2023 (25348)
Print this report* PEM Modify the magnetometer plots to the absolute value plot
* strain Add O3GK and the latest sensitivity plot to the strain curve plot
We finished the finalization work as the above lists. We will do the remaining tasks after O4a ends.
shoichi.oshino - 11:36 Wednesday 24 May 2023 (25355)
Print this reportAdd DISENGAGE_SUSLINES state of LSC_LOCK guardian (klog 25353). Add SYS_IPC guardian state to All-guardian page. Remove "Aligned" state from VIS-OpLev pages.