Abstract
I investigated the new candidate frequency for calibration lines.
I plan to move ETMX_TM line from 31.51Hz to 27.1Hz,
Pcal_1 line from 32.7Hz to 28.21Hz, and Pcal_2 line from 32.7Hz.
Details
For the better parameter estimation, I searched the non-peak frequency band in more lower frequency region.
But because of the relation between the pcal power and the sensitivity, it's difficult to use below 20Hz.
So I focused on moving from above 30Hz to below 30Hz and I found the non-peak band around 26-30Hz as shown in Fig.1.
Overall plot and exact frequency values can be found on DAC Wiki
Finally, I decided to move ETMX_TM and Pcal_1 lines to below 30Hz and Pcal_2 line to the frequency for Pcal_1 in previously.
I will compute the reference value of various transfer functions at the new line frequencies for tracking calibration lines on the real-time front-end.
After finishing the calculation, I will move to the calibration lines.