Reports 1-1 of 1 Clear search Modify search
DetChar (General)
shoichi.oshino - 16:18 Wednesday 29 March 2023 (24595) Print this report
Restarting Fscan
I restarted the Fscan process.
Now results of Fscan can be seen from SummaryPage.

Detail:
Fscan is working on k1det0 once a day with cron.
Currently, Fscan uses SIENCE_MODE segments for its process.
But the science mode has been not turned on during commissioning period, I switched segments list from SIENCE_MODE to LSC_LOCKED.
I also modified the channel name of the strain to K1:CAL-CS_PROC_DARM_STRAIN_DBL_DQ.
Fscan also generates plots of CAL-CS_PROC_DARM_DISPLACEMENT and CAL-CS_PROC_IMC_FREQUENCY channels.
Magnetometer channels are used in LIGO. If these channels are needed in KAGRA in the future, we will add them to Fscan.
I also checked the newer version of FscanDriver on LIGO GitLab but it doesn't work well.
Maybe the options of lalpulser_MakeSDFDAG are different from before so we need to modify that.
Search Help
×

Warning

×