Reports 1-1 of 1 Clear search Modify search
PEM (Center)
tatsuki.washimi - 9:29 Wednesday 29 March 2023 (24583) Print this report
Tapping test in the PSL room

[Akutsu, YokozaWashimi]

This morning (8:30~9:00 JST), we performed the tapping test in the PSL room. We found 2 remarkable things

  1. High power laser: when we tap the optical table near the high power laser, peaks around  400 Hz are excited.
  2. Beam duct: when we tap the beam duct going to the MCF chamber, the "shoulder shape" noise was excited. However, there is no excited noise when we put the shaker (60-2000Hz broadband) on the duct.
  3. A cable connected to the final periscope was not sensitive to the DARM

We could not find something when we tap other places. (We did not touch any optics.)

Images attached to this report
Comments to this report:
tatsuki.washimi - 9:39 Wednesday 29 March 2023 (24585) Print this report

Here there are other photos of the taping test, no significant excess in the DARM

Images attached to this comment
Search Help
×