shoichi.oshino - 10:31 Tuesday 14 March 2023 (24404) Print this report
Hveto result on Mar 11th
I checked and summarized Hveto result on Mar 11th.
Note that the unsafe channel list is not set and may contain auxiliary channels affected by DARM glitches.

Round 1 K1:IMC-MCE_PIT_OUT_DQ
Mainly, 87.5 Hz of DARM glitches have coincidence.
IMC-MCE_PIT has coincidence on two frequencies, but its frequency changed with the duration of the lock.
6~8 UTC : 18, 21.5 Hz
11~13 UTC : 21.5, 25.6 Hz

Round 2 K1:TMS-X_GR_QPDA1_YAW_OUT_DQ
Glitches are present over a wide frequency range, but glitch clusters that have coincidence exist at 300~400 Hz.
TMS-X_GR_QPDA1_YAW has coincidence glitches around 10~50 Hz.

Round 3 K1:ASC-AS_QPDA2_RF17_Q_YAW_OUT_DQ
Glitches have coincidence around 40~110 Hz.
ASC-AS_QPDA2_RF17_Q_YAW mainly has glitches around 40 Hz.
Comparing this result, it seems that both channels have glitch cluster around 40 Hz.

Round 4 K1:ASC-POP_FORWARD_QPDA2_DC_YAW_OUT_DQ
Mainly, 300~400 Hz glitches have coincidence.
On the other hand, 10~20 Hz glitches of ASC-POP_FORWARD_QPDA2_DC_YAW have coincidence.

Round 5 K1:PEM-SEIS_BS_GND_EW_IN1_DQ
Glitches have coincidence around 80~700 Hz.
PEM-SEIS_BS_GND_EW have coincidence around 30~200 Hz.

Round 6 K1:ASC-AS_QPDA1_RF17_Q_PIT_OUT_DQ
Glitches have coincidence around 10~80 Hz.
ASC-AS_QPDA1_RF17_Q_PIT have coincidence around 10~50 Hz.

Round 7 K1:VIS-PR3_IM_DAMP_V_IN1_DQ
Glitches have coincidence around 40~1000 Hz.
VIS-PR3_IM_DAMP_V has coincidence on 175.6, 300.8, 418.6, 485.5 Hz glitches.

Round 8 K1:ASC-POP_FORWARD_QPDA2_DC_PIT_OUT_DQ
347.3 and 349.5 Hz glitches have coincidence.
There are coincidence on the 10~20 Hz glitches.