takaaki.yokozawa - 8:36 Friday 03 March 2023 (24242) Print this report
Acoustic injection to PR booth (around 116Hz injection)
I performed the acoustic injection to PR booth.

I injected 111, 112, 113, 114, 115, 118 and 119Hz, and (maybe)only linear signal can be detected in DARM.

I injected the 116 and 117 Hz with various amplitude (Fig.1 and Fig.2)
The DARM noise became larger if larger amplitude injection performed.


Also, I injected signals between 116 and 118 Hz with same amplitude (Fig.3.)
116.5 Hz injection seems larger noise in DARM

Anyway, there are some moved peak around this frequency in micophone, if we can find the origin of this peak, we may get the hint to reduce the DARM noise around 100 -140 Hz.
(Fig.4. showed the 5 hour spectrogram this morning)
Images attached to this report