DGS (Test bench)shoichi.oshino - 18:12 Friday 03 February 2023 (23828)
Print this reportPreparation of Matlab on the workstation of test benchTo modify RT models on test bench system, I prepared Matlab for the workstation of test bench. First I copied Matlab 2016b from k1nfs0. After activating the license, I found that Matlab takes a long time to start. I could not solve this problem, so I decided to start Matlab by specifying the license file directly. I also copied k1export.m and startup.m files from the current k1boot. When I opened the RT model file, I noticed that the link to the CDS parts was broken. Previously CDS parts are installed in /opt/rtcds/rtscore, but in the new k1boot it is installed in /usr/share/advligorts. So I cannot use the files via NFS. Since advligorts can now be installed with apt, I will install this library directly in WS.