DetChar (General)shoichi.oshino - 17:08 Thursday 02 February 2023 (23810)
Print this reportAdd high pass filter to the strain channel on SummaryPageYamamoto-san mentioned that 10-70Hz of DARM sensitivity may be polluted by numerical error. This is because the ASD of the strain channel differs greatly between low and high frequencies. This difference is even greater at PRFPMI and needs to handle.
I compared the strain plotted in the following three settings. 1. FFT length 4s 2. FFT length 60s 3. FFT length 4s + high pass filter 10Hz
The data used are the following times: LSC_LOCK guardian state : PRFPMI_RF_LOCKED GPS time : 1359200000 - 1359200600
The attached files are the strain of each setting. 2 and 3 improve the strain by a few tens of Hz. Therefore, I choose setting 3 for SummaryPage.