Reports 1-1 of 1 Clear search Modify search
MIF (General)
hirotaka.yuzurihara - 18:36 Wednesday 01 February 2023 (23793) Print this report
Modification of LSC LOCK Guardian : shorten the iteration to find IR resonance

[Ushiba, Yuzu]

Related to issue during silent run, klog#23473

I modified the LSC_LOCK Guardian to shorten the time to pass this state. When we sweep the frequency, sometimes we find two resonances whose distance is FSR. Previous Guardian code can`t handle this issue. We solved this by taking the average of resonance frequencies.

After the modification, we can find the IR resonance by iterating thie state a few times. When the iteration was 3 times, it took 1 min 20 s.

I also implemented the counter of the iteration. See image.

Images attached to this report