DGS (Test bench)shoichi.oshino - 11:44 Tuesday 17 January 2023 (23605)
Print this reportLaunch RTPCI exchanged the HDD on k1boot to set up the Debian10 test bench at DAB. k1imc0 and k1ioo were able to launch with diskless system, but couldn't enter the console with any accounts. I checked the shadow file in the diskless directory and confirmed that it is the same as k1boot. It is possible that file sharing is not working properly.
Comments to this report:
shoichi.oshino - 15:21 Wednesday 18 January 2023 (23629)
Print this reportI checked the configuration of NFS on k1boot and found that parameters are not set on the diskless directory. Therefore, I put the same configuration of other directories to this line and reflect this change. After rebooting RTPC, I can log in to this computer.
shoichi.oshino - 13:57 Thursday 19 January 2023 (23649)
Print this reportI realized that it was due to something missing in my configuration file. In the future, the configuration file should be split up to gather common parts.