We built epics environment on k1script1 with epics-3.14.12.3_long which contains LIGO diffs.
build source:
Copy /kagra/apps/epics-3.14.12.3_long to /kagra/apps/epics-3.14.12.3_long-deb10
build directory:
/kagra/apps/epics-3.14.12.3_long-deb10
It was not possible to make as is in k1script1 Debian Version 10.6 environment.
I made the following changes referring to EPICS-3.14.12.6 and made.
. /configure/os/CONFIG_SITE.linux-x86_64.UnixCommon
Error content :
Stop:
In 3.14.12.6, the leading $ line was removed and commented out.
. Error in /src/libCom/test/epicsExceptionTest.cpp.
Error Description :
... /epicsExceptionTest.cpp:68:49: error: size of array is too large
char * p = new char [unsuccessfulNewSize];
^
... /epicsExceptionTest.cpp79:38: error: size of array is too large
char [unsuccessfulNewSize];
^
Correspondence :
src/libCom/test/Makefile
In 3.14.12.6, epicsExceptionTest was removed, so the relevant line was commented out.
Fixing environment variables
Created epics-user-env-script~deb10.sh based on /kagra/apps/etc/epics-user-env.csh
Add a call from k1script1 .bashrc
Next, we examined how to migrate ioc from k1script to k1scirpt1.
/opt/rtcds/kamioka/k1/target/
k1vac:
Copy all k1vac folders to k1vac-deb10
. /configure/RELEASE
After: EPICS_BASE=/kagra/apps/epics-deb10/base
After the change, we confirmed that we can BUILD by MAKE.