DetChar (General)shoichi.oshino - 15:38 Saturday 19 November 2022 (22970)
Print this reportSummaryPage updateI added trans IR and GR QPD signals to the ISC tab. These pages show PIT, YAW, and SUM of timeseries, spectrum, and spectrogram of two QPDs. LIGO's SummaryPage only shows IR QPDs. I assume this is due to the difference in optics between LIGO and KAGRA, but if GR information is excessive, please let me know.
During this work, I found that TMS-Y_IR_QPDA1_SUM and TMS-Y_IR_QPDA2_SUM channels aren't DAQ'd. I will add these channels to the DAQ list unless there is a specific reason not to.
Comments to this report:
shoichi.oshino - 16:21 Monday 28 November 2022 (23062)
Print this reportAccording to Ikeda-san's work(klog 23035), K1:TMS-Y_IR_QPDA1_SUM_OUT and K1:TMS-Y_IR_QPDA2_SUM_OUT channels are DAQ'd. Therefore, I added these plots to SummaryPage and it works well.