DetChar (General)shoichi.oshino - 13:01 Monday 17 October 2022 (22537)
Print this reportUpdate on SummaryPageI have made several updates on SummaryPage.
* VIS guardian state Related to the recent update for VIS guardian, low noise suspensions are enabled in the VIS guardian's observation state. The current SummaryPage creates plots only for Aligned state, so low noise states were not plotted. Since the current VIS guardian state configuration has a misaligned state between aligned and observation, I have separated the plot condition into two. One is the "Aligned" configuration for aligned state of VIS guardian. Other is the "Observing" configuration for observation state of VIS guardian. Note that the "Observing" configuration is not the observation state of the LSC_LOCK guardian.
* Range Currently, the channel displaying the inspiral range value (K1:DAS-RANGE) has stopped inputting data. Since LIGO uses a method to calculate the inspiral range directly from the h(t), I applied it. This method is using the function of Gwpy.