Modified Strain plots
After starting FPMI lock with low noise suspensions(klog 22422), the strain data plots on SummaryPage has been failed.
This problem is caused by the difference of guardian state and channel name.
Therefore, I modified these issues.

* Guardian
During O3GK, the number of "OBSERBATION" state of LSC_LOCK guardian was 1000, but now it becomes 10000.
This means that data from incorrect periods will be analyzed.

* Strain channel
The channel name of strain was modified after O3GK(klog 18580).
K1:CAL-CS_PROC_C00_STRAIN was renamed to K1:CAL-CS_PROC_DARM_STRAIN.

* Omicron
Omicron generator analyzed old channel name so I fixed it.

* Regenerate strain plots
After fixising above problems, I regenerated plots of strain channel on October 12th.