Calculation of SENS2EUL and EUL2COIL matrices for Type-Bp suspensions

[Yamamoto, Ushiba]

Abstract:
We calculated SENS2EUL and EUL2COIL matrices for Type-Bp's according to the geometrical parameters summarized in JGW-T2213979-v2.
Our calculation result is different from the current ones but our independent calculation results are the same, so it is likely that the current matrices are wrong.

Detail:
For the health check oof the PR suspensions, I started to check the SENS2EUL and EUL2COIL matrices.
Since my calculation result is different from current matrices, I asked Yamamoto-kun to cross check: then our independent calculation results are completely same.
So, it is likely thet current matrices are wrong.
So, I will change the matrices tomorrow and measured the TF with new matrices.