Reports 1-1 of 1 Clear search Modify search
VIS (General)
takaaki.yokozawa - 8:40 Friday 17 June 2022 (21161) Print this report
Investigation of MN oplev glitches
I also compared the sum value of IY and EY MN/PF oplevs (EX MN/PF oplevs are not center now, we will tune in future)

Fig.1. IY
State : Aligned state
This is the night time after setting the oplev windshield this Wednesday.
As you can see, there are correlated periodical glitch noise, but effect is not so dependent, not so independent.
The period is about 2 hour 45 min.

Fig.2. EY
No serious glitch was detected in EY.

From this result, the glitch is not caused by temperature, but may be caused by electrical(Instrumental) issue (Or ground issue?)
Images attached to this report
Search Help
×

Warning

×