tatsuki.washimi - 17:54 Thursday 07 April 2022 (20399) Print this report
Hammering (Shaker injection) for XPcal, 2022-04-07

[DanChen, Darkhan, Yokozawa, Washimi]

Today we performed the shaker injection test for XPcal.
Details are reported here. : https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=14019

When we shake the Rx module, Tx module, Leg of EXA, and body of EXA by the shaker (2~3 orders larger than normal), we couldn't see the excess in the Rx PD. 
Only when we rampaged on the square ground of the chamber (without touching the chamber body), we observed a little excess.

Images attached to this report
Comments to this report:
tatsuki.washimi - 13:07 Friday 08 April 2022 (20412) Print this report

I analyzed yesterday's data with the coupling function model.

Note that this analysis might not be appropriate for "Jogging" data, due to some non-linear coupling or multiple coupling paths.

Images attached to this comment
dan.chen - 16:38 Friday 08 April 2022 (20425) Print this report

I analyzed demodulated signal of Pcal lines, and the effect from the injected vibration on Pcal uncertainty could not be observed except for the "jogging" data.

Even in the case of jogging data, the generated uncertainty was about 0.3% at maximum.

Details: link

takaaki.yokozawa - 7:37 Thursday 21 April 2022 (20540) Print this report
I tried to evaluate the coherence between XPCal line and Sensors of ETMX suspensions.
IM photosensor, MN photosensor and BF LVDT are "NO" coherence with PCal lines.