Suspension modeling of ETMX

with Ushiba-san's help

I made suspension models of IP, BF, and BFGAS of ETMX.

These models were based on the Transfer functions measurement on Feb 18, which are stored at /kagra/Dropbox/Measurements/VIS/PLANT/ITMX/2022/02/PLANT_ETMX_STANDBY_IP_TEST_{L,T,Y}_202202181906.xml, /kagra/Dropbox/Measurements/VIS/PLANT/ITMX/2022/02/PLANT_ETMX_STANDBY_BF_TEST_{L,P,R,T,V,Y}_202202181906.xml, and /kagra/Dropbox/Measurements/VIS/PLANT/ITMX/2022/02/PLANT_ETMX_STANDBY_GAS_TEST_BF_202202181906.xml, respectively.

Then I stored these models at FM10(SUSMod_220218) of IP_IDAMP, BF_DAMP, GAS_DAMP filter banks respectively.

I haven't worked with GAS_F0~3 yet.

 

Images attached to this report
Comments to this report:
hiromi.yasui - 13:40 Monday 28 February 2022 (19914) Print this report

I made suspension models of GAS and MN of ETMX.

These models were based on the Transfer functions measurement on Feb 18, which are stored at /kagra/Dropbox/Measurements/VIS/PLANT/ITMX/2022/02/PLANT_ETMX_STANDBY_GAS_TEST_{F0,F1,F3}_202202181906.xml, /kagra/Dropbox/Measurements/VIS/PLANT/ITMX/2022/02/PLANT_ETMX_STANDBY_MN_TEST_{L,P,R,T,Y}_202202181906.xml, respectively.

Then I stored these models at FM10(SUSMod_220218) of GAS_DAMP and MN_DAMP filter banks respectively.