PEM (Center)takaaki.yokozawa - 13:37 Friday 18 February 2022 (19826)
Print this reportCabling for the PT100 temperature monitor at the PSL roomI finalized the cabling for the PT100 temperature monitor by cryocon at the PSL room today.
First, I connected the D-sub cable to cryocon which was placed behind of the PSL room. Next, I performed the cabling with the almost same place of the ondotori-pt100 (Fig.1.) - The position of the PT01(new) is very preliminary and after removing the PT01(old), we will replace it. - I didn't know what is the material on the PT04(old), I didn't touch it at this time - PT06 is placed temporary
I will try to record to KAGRA system soon.
Images attached to this report
Comments to this report:
tomotada.akutsu - 14:14 Friday 18 February 2022 (19828)
Print this report
The "old" PT04 might be set with a high-precision thermometer by Miyoki-san???
takaaki.yokozawa - 14:39 Friday 18 February 2022 (19829)
Print this report[Ikeda, Oshino, Yamamoto, Yokozawa]
With the help of them, we can set the epics channel for new PT100-cryocon temperature monitor at PSL room. Also we started the script to put the value to epics channel via crontab (Similar system with cryo monitors)
Channel names are K1:PEM-TEMPERATURE_TABLE_PSL_PT01 K1:PEM-TEMPERATURE_TABLE_PSL_PT02 K1:PEM-TEMPERATURE_TABLE_PSL_PT03 K1:PEM-TEMPERATURE_TABLE_PSL_PT04 K1:PEM-TEMPERATURE_TABLE_PSL_PT05 K1:PEM-TEMPERATURE_TABLE_PSL_PT06
satoru.ikeda - 15:33 Friday 18 February 2022 (19835)
Print this report
Additional Information K1:PEM-TEMPERATURE_TABLE_PSL_PT{01,02,03,04,05,06} adds EPICS channel to k1sdfmanage.