Reports 1-1 of 1 Clear search Modify search
DetChar (General)
takahiro.yamamoto - 15:16 Thursday 17 June 2021 (17150) Print this report
Glich trigger seach for MC Oplevs
Following channels are added to the automation channel list to omicron trigger search.
IMMT2 Oplev is not installed yet. But it may become a reference of electrical noise of IMC0 rack.

channels
K1:VIS-MCI_TM_WIT_PMON
K1:VIS-MCI_TM_WIT_YMON
K1:VIS-MCE_TM_WIT_PMON
K1:VIS-MCE_TM_WIT_YMON
K1:VIS-MCO_TM_WIT_PMON
K1:VIS-MCO_TM_WIT_YMON
K1:VIS-IMMT1_TM_WIT_PMON
K1:VIS-IMMT1_TM_WIT_YMON
K1:VIS-IMMT2_TM_WIT_PMON
K1:VIS-IMMT2_TM_WIT_YMON


Params
- Sampling: 256Hz
- Condition: IFO unlocked (instead of always)
Comments to this report:
hirotaka.yuzurihara - 22:16 Friday 18 June 2021 (17171) Print this report

To share the output of Omicron between workstations, I run rsync between k1sum1 and k1detfs0. After that, I turned on crontab for same rsync on k1sum1.

I added the description about this on wiki page.

hirotaka.yuzurihara - 6:12 Saturday 19 June 2021 (17175) Print this report

Glitch trigger is regularly running and generating trigger lists for oplevs of IMC. I updated the configuration for summary page to summarize these trigger lists. I attach an example for MCI-Yaw.(Fig.1)
At the bottom of summary page, there is a table of glitch triggers.(Fig.2) Usually there is button to link ligoDV. But, the KAGRA full data is unavailable on ligoDV. Instead, I set a link for Pastavi to see the several plots at the trigger time. The modification of gwsumm library is described in wiki page.