[Takahashi, Sato, Sugiyama, Ikeda(remote)]
We went to the adjustment of F0 vertical/yaw FR.
- The F1 keystone reached the upper limit. The keystone was pulled down with the FR.
- Checked the range of F0 vertical FR. Both upper and lower range was limited by stuck stepper motor. The movable range of F0 keystone was -14.4mm to -12.2mm. Though the upper limit due to the additional FR jig was removed, the range was not so improved.
- Moved the support ring by +25mm. Attached the secondary coils to the support ring.
- One of the side stoppers for BF was stuck. It was removed once and repaired.
- Tested the F0 yaw FR. The helicoil spring to pull the wire receptacle was still loose. It is necessary to arrange the location of stepper motor on the top plate to add other springs.
- Checked polarity of magnets in the BF damper.