DGS (General)takahiro.yamamoto - 11:34 Thursday 25 March 2021 (16327)
Print this reportRFM for X-arm is not available now.All RFM0 connections (X-arm) are now broken by some reason. I'll enter the mine...
Images attached to this report
Comments to this report:
takahiro.yamamoto - 13:52 Thursday 25 March 2021 (16328)
Print this reportA trouble seems to occur on K1IX1.
There is surely no light on RFM card on LSC (Fig1), ASC for X-arm network, and IX1 (Fig2). But RFM switch doesn't detect any connection trouble (Fig3).
By unplugging RFM cable of IX1, RFM connection on X-arm is recovered except k1ix1.
Images attached to this comment
takahiro.yamamoto - 16:01 Thursday 25 March 2021 (16330)
Print this reportFinally it was recovered by unplugging/re-plugging SFP module...
---- What I did 1. check lspci and dmesg => RFM card had been detected by OS and real-time model. 2. restart model => not solved 3. reboot model => not solved 4. replace SFP module for IX0 on the RFM switch as spare one => solved 5. put original SFP module back => works well... (why?)