Recovery of IMC suspension

[Sato, Takahashi, Horiuchi]

We went to recovery of the IMC suspensions. Some problems were pointed out by IOO (klog).

  • Stray cables from the coils in the MCi suspension were fixed onto the pillar with PEEK ties. The right side BNC connector (in the photo) was moved to the left side to close to the coil.
  • Cables from the coils in the MCo suspension were extended by 40cm. The Dsub 9pin connector was fixed onto the breadboard with brackets. The cables have not been fixed yet.
  • Loose Burndy female connector in the MCe was inserted to the inner part of male connector.
Images attached to this report
Comments to this report:
naohisa.satou - 19:51 Wednesday 17 February 2021 (16049) Print this report
Fix the MCo coil cable.
 
work on 2021.2.17 AM
Sato, Horiuchi
 
 * The MCo coil cable was fixed to the inner frame.
 * Checked the resistance of the coil from the relocated Dsub connector on the breadboard.
    (See attachment for the resistance values of coils)
Images attached to this comment