satoru.ikeda - 17:55 Wednesday 27 January 2021 (15845) Print this report
Comment to We investigated the network connection. (15737)

[ikeda, miyo-san, yamamoto-san, oshino-san, nakagaki-san]

We have investigated the network connection of both ends.
Please refer to JGWDoc for details.

JGW-E2112439-v16

We also checked the picomotor status of the X and Y-Ends.

In the ping test, there was no response in both ends.
X: Tried to connect to USB, but could not.
  Restarted after re-powering. Settings (IPADDR, GATEWAY, NETMASK) are fine.
  After re-powering, tried to connect to USB, but still could not connect.
  When I returned to Mozumi, I was able to connect to another Picomotor via USB, so it might be a problem with the USB connector on the Picomotor itself.
Y-end had the same problem as X, according to miyo-san's research, but I did not test the USB connector.

I left it connected for now to check the stability.