Reports 1-1 of 1 Clear search Modify search
VIS (BS)
satoru.ikeda - 19:58 Thursday 10 December 2020 (15625) Print this report
Install Model files for TypeB(SRM,SR2),TypeBp(PRM,PR2,PR3)

Separate the Type-Bp Model into Payload and Tower for the sake of commonality of the Model.

PRM: Installed

PR2,PR3: Model files have been created

Modify the Model of TypeB based on TOWER_MASTER

SRM: MON's GAS and IP connection was wrong, so fixed and installed

SR2: Installed

Non-image files attached to this report
Comments to this report:
satoru.ikeda - 12:30 Friday 11 December 2020 (15636) Print this report

The DCUID will be the following value.

K1PRM

[old] k1visprm: 55
[new] k1visprmt: 55, k1visprmp:56

K1PR2

[old] k1vispr2: 45
[new] k1vispr2t: 45, k1vispr2p:46

K1PR3

[old] k1vispr3: 50
[new] k1vispr3t: 50, k1vispr3p:51

Search Help
×