Reports 1-1 of 1 Clear search Modify search
IOO (IMC)
masayuki.nakano - 18:36 Thursday 18 June 2020 (14569) Print this report
IMC cavity pole measurement

The cavity pole was measured again. This might be the best measurement of the IMC cavity pole.
The attached plot is the TF from SLOW_OUT to IN1 of the IMC servo. The IMC was locked only with the PZT at this measurement. The results are as follows:

Cavity pole: 6.86(2) kHz 
DC gain: 2.692(3)

From these numbers and the PZT actuator efficiency 3.0 MHz (13012) and FSR 5.62 MHz, we can derive the following parameters

Optical gain: 0.897 V/MHz
Finesse: 409

Images attached to this report
Search Help
×