MIF (Noise Budget)
masayuki.nakano - 7:47 Thursday 20 February 2020 (13068) Print this report
CARM demod phase adjustment

[Aso, nakano]

I adjusted the demod phase of CARM error signal. I tweaked the demod phase by looking the sensitivity, and stopped when I feel best. It seems improved the sensitivity around 100 Hz.

Comments to this report:
shinji.miyoki - 8:28 Thursday 20 February 2020 (13072) Print this report

Yes, as  klog#13067, the improvement around 100-200 Hz is most effective for enhancing binary range.

 