tatsuki.washimi - 16:06 Monday 13 January 2020 (12486) Print this report
Preparation of the analysis code for the hammering test in Jan. 14

I developed the analysis code for the hammering test in Jan. 14, on k1sumX PC, with a dummy data. (fig.1, fig.2)

We will use the following channels :

  • K1:CAL-CS_PROC_DARM_DISPLACEMENT_DQ  : FPMI or PRFPMI
  • K1:PEM-SENSOR_BOOTH_EYA_BNC4_OUT_DQ : Accelerometer on the beam duct
  • K1:PEM-SENSOR_RACK_EY0_BNC4_OUT_DQ    : Impact hammer

 

Trigger : Peak time of the hammer RMS

ASD for the background :  [-36, -4] sec from the trigger time, fftlength=4s, overlap=2s

ASD for the pulse :  [-2, +30] sec from the trigger time, fftlength=4s, overlap=2s

 

The template of diaggui is also ready (fig.3) in /users/PEM/Hammering_20200114

Images attached to this report
Comments to this report:
tatsuki.washimi - 15:30 Tuesday 14 January 2020 (12497) Print this report

[Yokozawa, Washimi]

We prepaired the impact hammer and accelerometer in Y-end

Images attached to this comment