I made my first Noise Budget plot using Shoda-san's NoiseBudgetter tool.
10.68.10.57:8000/NoiseBudgetter/
https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=10917
http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Commissioning/NoiseBudgetter
Attached is the screenshot of my result.
The configuration file lives in:
/kagra/Dropbox/Subsystems/MIF/NoiseBudget/FPMI/NPconf_20191126_0137.csv
which reads:
0,Quantum noise (lossy),None,/kagra/Dropbox/Subsystems/MIF/NoiseBudget/FPMI/Noises/displacement_FPMIQuantumNoise_IBS400mW_FINESSE1500_lossy.txt
0,Suspension thermal noise,None,/kagra/Dropbox/Subsystems/MIF/NoiseBudget/FPMI/Noises/displacement_susp300K.txt
0,Mirror thermal noise,None,/kagra/Dropbox/Subsystems/MIF/NoiseBudget/FPMI/Noises/displacement_mirror300K.txt
0,Dark noise (1stage whitening),None,/kagra/Dropbox/Subsystems/MIF/NoiseBudget/FPMI/Noises/AS17_dark_1stagewhite_calibrated.txt
1,MICH control,K1:LSC-MICH1_IN1_DQ,None,None,None,,20;-10+10j;-10-10j,7.9e-6
We might be within an order of magnitude to quantum noise limited sensitivity.
Details:
- Suspension thermal noise and Mirror thermal noise
theoretical noise calculated by Somiya-san
- Quantum noise
theoretical noise calculated assuming 400 mW at BS, optical loss from BS to AS RF photodiode to be only 70% from SRM and two BS's on AS optical table.
- Dark noise
Measured by Anamaria, 1 whitening stage is on (klog #11747). Calibrated in a similar way as K1:CAL-CS_PROC_DARM_RESIDUAL, with an input matrix value 0.00633 (you actually also have to take into account the normalization factor with arm transmission, but the arm transmission is also normalized to 1, so it should be OK within ~10%).
AS17_dark_1stagewhite_rawcts.txt * 0.00633 * 3.10119495e-13 * (pole at 20 Hz)
- MICH control
K1:LSC-MICH1_IN1_DQ calibrated with the measured coupling by Yokozawa-san (klog #11344).
For the coupling, I used the eyeball fitted transfer function with pole at [20,-10+10*i,-10-10*i] Hz, DC gain of 1.9e-9 (see attached).
Next:
- Measure the actual optical loss and input power at BS
- Re-measure cavity pole and update the DARM reconstruction
- Try subtracting MICH control noise
- Incorporate more noise