VIS (BS)
ryutaro.takahashi - 23:53 Thursday 28 March 2024 (29004) Print this report
Replacement of feedthrough flange

[Ikeda, Washimi, Takahashi]

We replaced the P2 feedthrough flange.

  1. Checked the resistance between all pins in each Dsub connecter on the present flange (leaked previously) without the flip cables.
  2. Removed the present flange.
  3. Tagged a number and name to all Dsub connectors on the new flange.
  4. Connected the in-vacuum cables to the Dsub connectors.
  5. Closed the flange with two screws temporally.
  6. Checked the resistance between all pins in each Dsub connecter on the new flange without the flip cables.
  Old New Inductance

1:PI LV1

1-6

2-7

3-8

4-9

5-G

 

317Ω

248Ω

146Ω

OL

5.3Ω

 

317Ω

248Ω

146Ω

OL

OL

35.38mH

52.41mH

61.53mH

 

2:SF LV

1-6

2-7

3-8

4-9

5,6-G

 

198Ω

78.6Ω

111Ω

OL

3,6Ω

 

198Ω

78.7Ω

111Ω

OL

0,0.4Ω

39.21mH

10.12mH

68.95mH

 

3:TM H2

1-6

2-7

3-8

4-9

5-G

 

OL

18.5Ω

OL

OL

1.4Ω

 

OL

18.6Ω

OL

OL

OL

 

8.631mH

 

 

4:F0 LV

1-6

2-7

3-8

4-9

5-G

 

196Ω

77.3Ω

114Ω

OL

1.7Ω

 

196Ω

77.1Ω

114Ω

OL

0.5Ω

42.59mH

10.56mH

73.79mH

 

5:PI FR

1-6

2-7

3-8

4-9

 

5.0Ω

4.7Ω

3.2Ω

3.3Ω

 

4.8Ω

4.8Ω

3.2Ω

3.3Ω

 

 

 

 

 

6:IM H1

1-6

2-7

3-8

4-9

5-G

 

5.8MΩ

17.8Ω

OL

OL

2.3Ω

 

5.8MΩ

17.7Ω

OL

OL

4.3Ω

0.531V(6+)

8.357mH

1.70V(3+)

 

7:TM H3

1-6

2-7

3-8

4-9

5-G

 

OL

18.5Ω

OL

OL

10.6Ω

 

OL

18.5Ω

OL

OL

OL

 

8.662mH

 

 

8:PI SM

1-6

2-7

3-8

4-9

 

6.3Ω

6.9Ω

6.1Ω

5.1Ω

 

6.6Ω

6.8Ω

6.1Ω

5.2Ω

 

 

 

 

 

The Pin-6 in P2-2(SF LV) was grounded. There were not any other cross-connections. Though the Pin-5 in P2-1, P2-3, and P2-7 were grounded, they were floated after the flange replacement. It may be due to the condition of the aluminum foil covering the Dsub connectors.

Images attached to this report
Comments to this report:
tatsuki.washimi - 15:51 Friday 29 March 2024 (29014) Print this report

Photo of the inside. (white tapes are temporary attached)

Images attached to this comment
ryutaro.takahashi - 23:52 Thursday 04 April 2024 (29088) Print this report

[Hirata, Washimi, Takahashi]

We removed aluminum foils from the in-vacuum Dsub connectors at the P2 feedthrough flange. Some cables for 2:SF-LV, 3:TM-H2, and 6:IM-H1 were cut at the Dsub connectors during this work. They were repaired. The flange was closed with screws temporally. We checked the resistance between all pins in each Dsub connecter on the flange without the flip cables. 

  Before After Inductance

1:PI LV1

1-6

2-7

3-8

4-9

5-G

 

317Ω

248Ω

146Ω

OL

OL

 

317Ω

248Ω

146Ω

OL

OL

35.34mH

52.41mH

61.54mH

 

2:SF LV

1-6

2-7

3-8

4-9

5,6-G

 

198Ω

78.7Ω

111Ω

OL

0,0.4Ω

 

198Ω

78.5Ω

111Ω

OL

0,1.7Ω

39.16mH

10.11mH

68.99mH

 

3:TM H2

1-6

2-7

3-8

4-9

5-G

 

OL

18.6Ω

OL

OL

OL

 

OL

18.6Ω

OL

OL

OL

 

8.635mH

 

 

4:F0 LV

1-6

2-7

3-8

4-9

5-G

 

196Ω

77.1Ω

114Ω

OL

0.5Ω

 

196Ω

77.0Ω

114Ω

OL

OL

42.58mH

10.57mH

73.96mH

 

5:PI FR

1-6

2-7

3-8

4-9

 

4.8Ω

4.8Ω

3.2Ω

3.3Ω

 

5.1Ω

5.1Ω

3.2Ω

3.3Ω

 

 

 

 

 

6:IM H1

1-6

2-7

3-8

4-9

5-G

 

5.8MΩ

17.7Ω

OL

OL

4.3Ω

 

5.8MΩ

18.1Ω

OL

OL

0.0Ω

0.449V(6+)

8.357mH

0.950V(3+)

 

7:TM H3

1-6

2-7

3-8

4-9

5-G

 

OL

18.5Ω

OL

OL

OL

 

OL

18.7Ω

OL

OL

OL

 

8.662mH

 

 

8:PI SM

1-6

2-7

3-8

4-9

 

6.6Ω

6.8Ω

6.1Ω

5.2Ω

 

6.0Ω

7.0Ω

6.1Ω

6.1Ω

 

 

 

 

 

 

Images attached to this comment
ryutaro.takahashi - 17:02 Tuesday 09 April 2024 (29146) Print this report

[Washimi, Takahashi]

We closed the replaced feedthrough flange with the screws completely. The torque was 15N-m.

Search Help
×