IOO (General)tomotada.akutsu - 20:18 Thursday 25 April 2024 (29333)
Print this reportLO for PMC mysteriously reduced
Ushiba, Hirata, Akutsu
During AOS works, IMC or even PMC suddenly became unable to be locked. In my view, this happened when I requested PROVIDING_STABLE_LIGHT to IO Guadian from PSL_LOCKED. Anyway, Ushiba-kun pointed out that LO level was under the threshold. We were not sure what is the "LO monitor" channel meant in percent, but I found that the LO signal generator in the PSL room displayed 8.1 dBm while its nominal power should be 8.6 dBm according to a label attached on its body. I tweaked a knob on the signal generator to tweak the displayed output power to 8.6 dBm, but Ushiba-kun said that the "LO monitor" signal was still slightly under the threshold, so I tweaked it to 8.7 dBm, then PSL and IMC lock came back.
I have no idea why and how this happened. Looking at the "LO monitor" to the past, actually recently sudden reduction of the output power were sometimes observed. So this might repeat again.
One hint might be that I saw a kind of "unstable" state changing in IO Guadtian when I requested PSL_LOCKED when I finished works before lunch (but aruond 13:30). What I did before this was just requesting PROVIDING_STABLE_LIGHT to IO Guardian, and then requested HOLD_ALIGNMENT.
LAS (High Power Laser R&D)tomoyuki.uehara - 19:21 Thursday 25 April 2024 (29332)
Print this reportneoLASE-laser power measuremant[Miyakawa, Uehara, Endo, Kato] -We aligned the seed laser to the solid amplifier to maximize the output power. -After the alighnment, we measured the laser light power against the injection current of the optical amplifier using a Thorlab power meter (calibrated) and a Gentec power meter (not calibrated). Attached figure (laser_IP-chara.png) is the characteristics. The laser power measured by Thorlabs is 1.22 times higher than Gentec's. -We set a box (box.jpg) for beam profile measurements later.
Images attached to this report
CAL (XPcal)dan.chen - 17:01 Thursday 25 April 2024 (29331)
Print this reportComment to Alignment change because of the pumping? (29150)
With Hido Shingo
We performed the fine adjustment for the Pcal-X alignment with the ALIGNED state of the ETMX suspension. We used PCAL_EX1(in Tx module) and PCAL_EX2(in EXA chamber) picomotors to adjust the path 1 so that the paths passed through the design position on the ETM and the center of the RxPD. We left the Pcal-X laser ON, and the Pcal-X guardian state at OFS_CLOSED_LOW_POWER.
Attached files are showing beam positions on ETM and RxPD.
The total picomotor steps we requested are:
PCAL_EX1, pico 2 (path 1 yaw): -550
PCAL_EX2, pico 1(path 1 yaw): -600
PCAL_EX2, pico 2(path 1 pitch): +400
PCAL_EX2, pico 3(path 2 yaw): +100
PCAL_EX2, pico 4(path 2 pitch): +300
The final optical efficiencies were (quick measurement):
CAL (General)hirotaka.yuzurihara - 16:38 Thursday 25 April 2024 (29330)
Print this reportThe mirror centers after recovery works
By analyzing the recent TCam images, I identified the mirror center of ETMX, ITMX, and ITMY. When the ETMY or GreenY is ready, we will try to take the ETMY image and identify the mirror center.
Details
For ETMX, I had an accidental chance to take the TCam for ETMX illuminated by Greenx on 4/23 (during adjustment work of PR2). For ITMX and ITMY, the image was taken on 3/15 (klog#28863).
Note that the ETMX image was taken after the evacuation an the ITMX and ITMY images were taken before the evacuation.
From this analysis, I updated the fixed radiuss of 1243 pixel which was computed from the conversion factor of 10/113 = 0.0885 [mm/pixel]. This was evaluated from the metal-scale-insert test(klog#28843).
From the metal-scale-insert test(klog#28843), I evaluated the conversion factor as 10/60 = 0.167 [mm/pixel]. Accordingly, the mirror radius could be 660 pixel. But, this estimation has large uncertainty. If one pixel changes in the estimation, the mirror radius changes 600~733 pixel. I decided to use the fixed radius of 630 pixel which we evaluated by hand fitting with Aogaku members previously, because this value has the small uncertainty than the metal-scale-insert test.
VAC (EYA)nobuhiro.kimura - 15:37 Thursday 25 April 2024 (29329)
Print this reportComment to Pool of liquid in EYA chamber (29214)
[Kimura and M. Takahashi]
To identify the source of the liquid material that entered the EYA tank, three filters of the air compressor and the inside of the connection piping of the dry pumps for vacuum pumping were visually inspected. As a result of the visual inspection, no traces of liquid material were found inside the filters of the air compressor and the connecting piping of the dry pumps for vacuum pumping. The smell inside the filter and piping was confirmed by nose, but the same irritating smell observed in the EYA tank was not found. Three filters of the air compressor were replaced with new ones because more than two years had passed since the last replacement.
DetChar (General)nami.uchikata - 14:50 Thursday 25 April 2024 (29328)
Print this reportComment to Omicron triggers at System B (28010)It seems the failure is caused by glitches from the IPC error. I have already made segments that excludes the IPC error segments from the science mode. /home/detchar/Segments/K1-GRD_SCIENCE_MODE_NO_IPC_ERROR
VAC (General)nobuhiro.kimura - 14:42 Thursday 25 April 2024 (29326)
Print this reportResults of vacuum leak test results for the new pressure gages of GVetmx and GVetmy
[Kimura and Ueda (SKS) ] On the afternoon of 18 Apr., Ueda-san and me performed a vacuum leak test for new pressure gage of GVetmx. The results of the vacuum leak test confirmed that the new pressure gage of GVetmx did not leak more than 1x10^-12 Pam^3/s.
[Kimura, and M. Takahasshi] On the morning of 25 Apr., M. Takahashi-san and me performed a vacuum leak test for new pressure gage of GVetmy. (See attached photos 1~2) The results of the vacuum leak test confirmed that the new pressure gage of GVetmy did not leak more than 1x10^-12 Pam^3/s. After the leak test, we set up protection panel in front of the gage. (See attached photo 3)
The protection panel for the gage of GVetmx was set up, too.
Images attached to this report
VAC (IX)takashi.uchiyama - 14:38 Thursday 25 April 2024 (29327)
Print this reportComment to Pumping down IXC (29307)2024/04/25
Uchiyama
I turned on 4 TMPs to pump down IXC at around 9:45.
VIS (OMM)tatsuki.washimi - 13:55 Thursday 25 April 2024 (29325)
Print this reportComment to Visual inspection of Stack (29245)
[YokozaWashimi, Ishikawa, Ozaki, Sudo]
We performed hammering tests (vertical tapping) for the OMC in-vac table. The tapped points are the table, the base plate, and the ground near the stack1 or 2.
Images attached to this comment
VIS (General)kenta.tanaka - 13:44 Thursday 25 April 2024 (29324)
Print this reportComment to Gentle turning off method of dewhitening filters of coil drivers (29139)
Yamamoto, Tanaka
We modified the setting from 'Zero_histroy' mode to 'Always_on' mode in the COILOUTF filters for all of suspensions.
Also, we loaded the setting for all COILOUTF filters around 13:30 JST 4/25 2024, except for ETMX, ITMY, PRM, PR2 which someone use in this time.
VIS (SRM)takafumi.ushiba - 10:55 Thursday 25 April 2024 (29323)
Print this reportComment to Visual inspection of SRM suspension (29317)
According to the health check in January, gain of OSEM #3 (H2) and #4 (V3) are 3 dB and 5 dB smaller than before the earthquake, respectively (fig1 and 2).
Note:
Somehow, SRM IM OSEM TFs have lower gain (2-5 dB) than before the earthquake not only in H2 and V3 but also the others (fig3: case of H3). Further investigation is necessary.
Images attached to this comment
VIS (SR2)takafumi.ushiba - 10:37 Thursday 25 April 2024 (29322)
Print this reportComment to Visual inspection of SR2 suspension (29315)
According to the health check in January, gain of OSEM #1 (H3) has almost no change before and after the earthquake.
Images attached to this comment
VIS (SR3)takafumi.ushiba - 10:34 Thursday 25 April 2024 (29321)
Print this reportComment to Visual inspection of SR3 suspension (29316)
According to the health check in January, gain of OSEM #2 (H1) is about 1dB smallerthan before the earthquake (fig1).
Images attached to this comment
VIS (IMM)takafumi.ushiba - 9:10 Thursday 25 April 2024 (29320)
Print this reportHealth check of IMMT2
I performd health check of IMMT2 (fig1 - fig7). All TFs seem fine.
Images attached to this report
VIS (IMM)takafumi.ushiba - 9:02 Thursday 25 April 2024 (29319)
Print this reportHealth check of IMMT1
I performd health check of IMMT1 (fig1 - fig7). All TFs seem fine.
Images attached to this report
PEM (Center)takaaki.yokozawa - 7:45 Thursday 25 April 2024 (29318)
Print this reportMeasurement of the vibration on the vactable of the OMC[YokozaWashimi, Ozaki, Sudo]
We performed the measurement of the vibration spectrum using the 3axis accelerometer. Totally, 10 position measurement were performed. The summary will be appeared soon.
Images attached to this report
VIS (SRM)ryutaro.takahashi - 0:08 Thursday 25 April 2024 (29317)
Print this reportVisual inspection of SRM suspension
[Ikeda, Takahashi]
We checked the OSEMs visually. The flap of OSEM#3 and #4 in the IM was rotated more than 40°.
Images attached to this report
Comments to this report:
takafumi.ushiba - 10:55 Thursday 25 April 2024 (29323)
Print this report
According to the health check in January, gain of OSEM #3 (H2) and #4 (V3) are 3 dB and 5 dB smaller than before the earthquake, respectively (fig1 and 2).
Note:
Somehow, SRM IM OSEM TFs have lower gain (2-5 dB) than before the earthquake not only in H2 and V3 but also the others (fig3: case of H3). Further investigation is necessary.
Images attached to this comment
VIS (SR3)ryutaro.takahashi - 23:46 Wednesday 24 April 2024 (29316)
Print this reportVisual inspection of SR3 suspension
[Ikeda, Takahashi]
We checked the OSEMs visually. The flap of OSEM#2 in the IM was rotated more than 40°.
Images attached to this report
Comments to this report:
takafumi.ushiba - 10:34 Thursday 25 April 2024 (29321)
Print this report
According to the health check in January, gain of OSEM #2 (H1) is about 1dB smallerthan before the earthquake (fig1).
Images attached to this comment
VIS (SR2)ryutaro.takahashi - 23:13 Wednesday 24 April 2024 (29315)
Print this reportVisual inspection of SR2 suspension
[Ikeda, Takahashi]
We checked the OSEMs visually. The flap of OSEM#1 in the IM was rotated more than 40°.
Images attached to this report
Comments to this report:
takafumi.ushiba - 10:37 Thursday 25 April 2024 (29322)
Print this report
According to the health check in January, gain of OSEM #1 (H3) has almost no change before and after the earthquake.
Images attached to this comment
VIS (IMM)ryutaro.takahashi - 22:19 Wednesday 24 April 2024 (29314)
Print this reportVisual inspection of IMMT2 suspension
[Takahashi, Ikeda, Hirata, Ushiba]
We checked the IMMT2 suspension visually. There was a small margin of the Pico-motor range for the pitch direction. There was no margin for yaw CCW direction (<1mm). There were not any rubbing magnets in the IM.
Images attached to this report
VIS (IMM)ryutaro.takahashi - 21:50 Wednesday 24 April 2024 (29313)
Print this reportVisual inspection of IMMT1 suspension
[Takahashi, Ikeda, Hirata, Ushiba]
We checked the IMMT1 suspension visually. There were margins of the pico-motor range much enough to adjust both pitch and yaw motion. There were not any rubbing magnets in the IM. When we took the pictures with a fiber scope touching the EQ stop frame, the TM pitch jumped due to a weak joint in the X-Y stage supporting the frame.
Images attached to this report
MIF (General)naoatsu.hirata - 20:56 Wednesday 24 April 2024 (29312)
Print this reportComment to Finalization of IFI-IMM-PRM: Day 4; Re-alignment of IMMT1, IMMT2, and PRM (29299)
[Hirata, Ushiba-san, Ikeda-san]
We checked IR beam position around PR2 HR side Mid-size baffle. (How to make the vertical line is same as klog:29282) It looks that IR beam positon is about 3.5mm +Y side away from the center of aperture.(IR beam center is 68.5mm and aperture center is 72mm on the ruler.)
Images attached to this comment
FCL (Water)tatsuki.washimi - 18:13 Wednesday 24 April 2024 (29311)
Print this reportComment to Y-arm mine water and pumps (29047)
The readout of the water fluid has recovered.
Images attached to this comment
VIS (OMM)tatsuki.washimi - 17:54 Wednesday 24 April 2024 (29310)
Print this reportComment to Visual inspection of Stack (29245)
[YokozaWashimi, Tanaka, Ozaki, Sudo]
Today we tried to evaluate the seismic isolation of the OMC stacks, using a 3-axial accelerometer (S2315344) and an impact hammer (G1910656). This is a quick report.
Locating the ACC on the OMC vac-table (Fig.1, Fig.2)
Tapping each stack (top, middle, bottom of stack1, stack2) with the impact hammer (direction: Fig.3)
Picking up each pulse (-0.2/+0.8 sec) and calibrating its transfer functions from impact [N] to acceleration [m/s2] automatically (example: Fig.4, Fig.5)
Calculating averages of the events (Fig.6, Fig.7)
Images attached to this comment
LAS (High Power Laser R&D)tomoyuki.uehara - 16:42 Wednesday 24 April 2024 (29309)
Print this reportneoLASE laser [Miyakawa, Uehara] We checked some laser operations. And we set a mirror for beam profile measument later(fig1).