Comment to Recovery of the BS suspension after pump down. (8125)

Here are more TF measurements. Comments are:

  • F1: the TFs have a different offsets. This is likely related with the different postions of the keystones. See entry 8117. The resonant frequencies are the same.
  • IP Longitudinal: the resonant frequency is 39 mHz. The phase requires checking.
  • IL Transverse: the resonant frequency is 93 mHz. The phase requires checking.
  • IP Yaw: the lowest resonance frequency is 38 mHz. The following one is 132 mHz.

The TF for the BF and F0 are still missing.