TypeA,B,Bp VIS Guardian changed to SAFE

Before the start of the DGS maintenance day, we changed the suspension status of the VIS.

  • The following suspensions were changed from ALIGNED to SAFE

 ETMX, ITMX, PR3
 ETMX, ITMX, and PR3 were all CONFIRMed because they had a difference in SDF in the SAFE state.

  • ITMX had a difference in SDF in ALIGNED state, but this was REVERTed.